8 Channel Amplifier Fault Changeover with Speaker Line Surveillance TS-800

The TS-800 8 channel amplifier fault auto-changeover with speaker line impedance surveillance is an integrated controller integrates the amplifier fault changeover with the speaker line surveillance into one 19 inch 1U unit.

Product Details

Description:


The 8 channel amplifier fault auto-changeover with speaker line impedance surveillance is an integrated controller integrates the amplifier fault changeover with the speaker line surveillance into one 19” 1U unit. The amplifier fault auto changeover will automatically switch into standby amplifier once there is anyone of the 8 main amplifiers failure. The switching time is within 1 second. The speaker line impedance supervision enables to supervise the speaker line open circuit, short circuit and impedance fluctuation. Each zone detection time is within 2 seconds, The amplifier fault and speaker line fault will be reminded by front panel visualized indicator, buzzer and fault contact or RS485 contact to third party system. The amplifier fault changeover and speaker line surveillance unit is design with full visual indication. There are 8 amplifiers working status indicators, green of normal, yellow of standby and red of fault and distinguished of non-used. There are 8 speaker lines monitoring status indicators, green of normal, yellow of standby and red of fault and distinguished of non-used. There are 8 line inputs from audio sources and 8 line outputs to main amplifiers, 8 100V inputs from main amplifiers and 8 zone 100V outputs to speakers. One total fault output, one RS485 output to inter-work with third party system. Dipswitch to enable or disable the monitoring. Various supervision period selection through rear panel dipswitch. One calibrate button on front panel to initialize or calibrate each amplifier and speaker line setting. Speaker line impedance surveillance is of10% fluctuation. Expandable from 8 zones to max 192 zones. 24V DC operation system.


Feature:

8 Channel amplifier fault changeover with speaker line surveillance

19” rack mount design in 1U height

One standby amplifier to backup 1 to 8 main amplifiers within 1 second

8 speaker line supervision for open circuit, short circuit and impedance fluctuation

Each speaker zone detection time within 2 seconds

The amplifier and speaker line fault will be reminded by indicator, buzzer, fault out and RS485 out

8 amplifier indicator, standby amplifier indicator and 8 speaker line indicator

With calibrate button on front panel to initialize or calibrate each amplifier and speaker line setting

8 line inputs from audio sources and 8 line outputs to main amplifiers

8 100V inputs from main amplifiers and 8 zone 100V outputs to speakers

Dipswitch for 8 zone enable or disable the monitoring

Various supervision period selection through rear panel dipswitch

10% speaker impedance surveillance

Expandable from 8 zones to max 192 zones

24V DC operation system


Specs:


Model

TS-800

Description

8 Channel Amplifier Fault Changeover with Speaker Line Surveillance

Channel

8 Channels

Connector

Eight balanced line inputs from audio sources by phoenix connector

Eight balanced line outputs to main amplifier by phoenix connector

Eight 100V inputs from main amplifiers by phoenix connector

Eight zone 100V outputs to speakers by phoenix connector

One total fault contact output by phoenix connector & One RS485 output by RJ45

One line input and line output for backup amplifier by phoenix connector

One 100V input from backup amplifier by phoenix connector

Configuration

Auto or manual monitoring dipswitch; Enable or disabled 8 zone monitoring dipswitch

Expandable to 192 zones ID dipswitch; 10% monitoring speaker line fluctuation

Input Sensitivity/Impedance

1V, 10K Ohm

Pilot Tone Frequency

20 KHz (±5%)

Detection Line

50V/70V/100V Speaker line

Detection Level

50V rms min

Amplifier Detection Time

< 1 Second

Speaker Line Detection Time

< 2 Seconds per speaker zone

Changeover Time

< 1 Second

Failure Detection Time

5-15 Seconds

Failure Reset Time

20 Seconds Max.

Zone Loading Capacity

500W /100V Line Max.

Max Loading Current

8A

Measurement Sensitivity

±10% of Speaker line impedance

Power Supply

24V DC by phoenix connector Max. 2A

Dimension

484x420x44 mm

Weight

3.2kg