16 zone speaker selector DCI-13A

DCI-13A is a 16 zone matrix that integrates BGM, zone paging broadcast and alarming. It connects the output signal of the power amplifier at the front end to the speaker at the back end.

Product Details

Descriptions:


DCI-13A is a 16 zone matrix that integrates BGM, zone paging broadcast and alarming. It connects the output signal of the power amplifier at the front end to the speaker at the back end. It mainly realize three functions:

1. It can convey the output signal of the power amplifier into 16 broadcast zones;

2. It can work with DCI-10P to achieve zone paging. When make zone calls, only the selected zones would be addressed,while other zones play music as normal as before;

3. It also can activate the alarm. When there is an alarm signal input, it can automatically switch to the alarm zone to sound the alarm, while other zones can play background music normally as before.

DCI-13A has 4 background music amplifier signal access terminals and 4 emergency music (paging or alarm) amplifier signal access terminals, with 1 input terminal (1-4, 5-8, 9-12, 13-16) for every 4 zones. If you want to achieve zone paging or zone alarm, you need to connect a paging or alarm amplifier, or you can share one amplifier for paging and alarm.



Features:


1. Can be controlled by DCI-100.

2. The address was encoded in decimal and the machine address would be displayed clearly;

3. Equipped with a 128 * 64 LCD display screen, Chinese/English menu operation, and program timing switching for each and all zones .

4. 16 zone switch control, fully support the unique power stacking function of this series of amplifiers for connection and use;

5. Four alarm sound source signal inputs (70V/100V audio) and four background sound source inputs (70V/100V audio);

6. 25 pin computer activation interface, low-level alarm activation.

7. Equipped with remote on/off function, remote partition control function, remote device status reading function, support for program download and system automatic timing function;

8. The total control power capacity of the partition can reach 3KW;

9. Equipped with short-circuit signal activation and startup function, used for emergency fire broadcasting;


Specifications:


Model: DCI-13A

Group A input:70V/100V, audio (background) signal "CH1~CH4"

Group B input:70V/100V, audio (background) signal "CH5~CH8"

Group C input:70V/100V, audio (background) signal "CH9~CH12"

D group input:70V/100V, audio (background) signal "CH13~CH16"

E1 group input:70V/100V, emergency broadcast (alarm) audio signal "CH1~CH4"

E2 group input:70V/100V, emergency broadcast (alarm) audio signal "CH4~CH8"

E3 group input:70V/100V, emergency broadcast (alarm) audio signal "CH9~CH12"

E4 group input;70V/100V, emergency broadcast (alarm) audio signal "CH13~CH16"

Number of controllable zones:16 zones (CH1~CH16)

Zone output control:

                    Can manually choose to output background audio signals or activate 

                    any partition to output alarm audio signals through alarm signals

Controlled zone output capacity:

                        Total capacity of audio signal input: 1.5 KW; 

                         Each corresponding partition can output a  

                         maximum load capacity of 1.5 KW; 

                        Total capacity for emergency broadcast (alarm) audio signal input: 1.5 Kw.            

                

Channel switching capability:1.5 KW, audio signal

Alarm signal input:Short circuit signal (ALARM IN)

Alarm signal output:Short circuit signal (ALARM OUT)

Alarm activation signal:Short circuit signal ACTIVE OUT

Functional control:One power switch key, sixteen manual selection buttons, 

                               three menu operation keys (UP,  DOWN, ENTER), one full 

                               open key and one full key, one online control interface, 

                               one short-circuit power activation port, and one device address 

                               setting switch (1 position)

Indicator light:Power indicator light POWER, CH1~CH16 open status indicator 

                        light and alarm status indicator light

Protect:AC FUSE × 0.5A × one

Power cord:(3) × 0.5 mm2) × 1.5M (standard)

Power: source:AC 220V ± 10% 50-60Hz

Power consumption:20-30W

Machine dimensions:133 (H) × 483 (W) × 390 (D) mm

Packaging box size:185 (H) × 520 (W) × 455 (D) mm

Net weight:9.9Kg

Gross weight:11.1KG