DC-10P is public address controller with 16 zone output and paging controller ideal for cost effective background music system with paging and voice alarm functions.
Description:
DCI-10P is public address controller , usually work with a divider (DCI-13B or DCI-13A). It can broadcast to 16 zones. When making public address, only the selected zone would be addressed, while other zones play background music normally. It can also be connected to a paging microphone for long-distance broadcast. Each device can connect up to 4 paging microphones.
Features:
1. Can be zoned by DCI-100.
2. The address was encoded in decimal and the machine address would be displayed clearly.
3. LCD display the operation proccess, intuitive and user-friendly.
4. It can achieve paging selection for 16 zones.
5. Equipped with online control function, remote on/off function, and total volume remote control function;
6. Has 4 levels of priority, namely MIC1>emergency input (alarm)>paging MIC1>paging MIC2, MIC3, MIC4, and line input;
7. Using a 25 pin computer activation interface, low-level alarm activation.
8. Can connect to DCI-10R paging microphone for remote control operation,
9. Built in clock synthesis circuit, professional level clock sound prompt sound effect, can remotely control the playback of clock sounds;
10. Equipped with short-circuit signal activation and startup function, used for fire alarm;
Specifications:
Equipment model DCI-10P
Emergency input port EMC: 10k ohms (Ω) 330mV, unbalanced
Microphone input MIC: 600 ohms (Ω) 5mV, unbalanced
Paging microphone input port: 4sets of RMIC1, RMIC2, RMIC3, and RMIC4: 10k ohms (Ω) 10V, balanced
Line input port:LINE: 10k ohms (Ω) 330mV, unbalanced
Line output:10k ohms (Ω) 0.775V (0 dB), unbalanced
Frequency response:60 Hz~16k Hz (± 3 dB)
Nonlinear distortion THD:<0.01% at 1kHz
Signal to noise ratio S/N:>70 dB
Number of controllable Zones:16 zones "CH1~CH16"
Zoneing output control:Can be manually selected or activated by alarm signals for any zone
Alarm activation input port:(0v) Short circuit signal alarm IN (CH1~CH16)
Alarm activation output port:(0v) Short circuit signal alarm OUT (CH1~CH16)
Alarm activation output port:2 sets of short-circuit signals (ACTIVE OUT)
Silent suppression ability:The local MIC and chime sound are of the highest priority, the emergency audio signal (EMC) is of the second level, the paging microphone 1 (RMIC1) is of the third level, and the paging microphones 2, 3, 4 (RMIC2, 3, 4) and line (LINE) are of the fourth level; Remark: Signal attenuation of 0-30 dB
Functional control:
Two volume adjustment buttons (VOL+, VOL -), sixteen manual selection buttons, one power on button, one full on button, one full on button, one address setting switch (1 position), one prompt tone button, four paging microphone interfaces RMIC1~RMIC4, one line input port, one emergency input port, one LCD display screen, one MIC volume adjustment knob, one prompt tone volume adjustment knob, and one main power switch, Two online control interfaces and one short-circuit power activation port
Indicator light: POWER, sixteen zones CH1~CH16 Volume control
Output total volume: 32 levels, CNC, can be remotely controlled through PC
MIC volume: potentiometer adjustment
Protect:AC FUSE × 0.5A × one
Power cable:(3) × 0.5 mm2) × 1.5M (standard)
Power source:AC 220V ± 10% 50-60Hz
Power consumption:10-15W
Machine dimensions:89 (H) × 483 (W) × 350 (D) mm
Packaging size:145 (H) × 520 (W) × 435 (D) mm
Net weight:5.4Kg
Gross weight:6.6Kg